1、<p><b>  外文資料及翻譯</b></p><p>  Fire in high-rise building design</p><p>  Fire in high-rise building design in recent years, the city's commercial and residential design proc

2、ess, encountered a new problem is the fire department for public security for a class of high-rise residential elevators and the Office of Public hallway with Automatic sprinkler fire extinguishing system. Past, Design f

3、or the present "Tall Buildings design of fire safety regulations" (GB 50045-1995) (hereinafter "high regulation"), automatic sprinkler system installed .6.2 scope of section 7 of t</p><p>

4、;  Section 2 of Chapter VII of the fire water, we can see a kind of high-rise building fire hydrant water for the indoor 20 L / s, and a category of high-rise commercial indoor water hydrant to 40 L / s, the difference w

5、as doubled. To a 30-storey residential buildings and a composite of the same height (24m following skirt building for commercial purposes, for its residential) as an example, to analyze the fire danger. For composite ski

6、rt building, as shopping malls, restaurants, etc., because of t</p><p>  Most residential tower floor of the typical residential floor elevator and the Office of the general public sidewalk installation of 5

7、 ~ 8 nozzle it will satisfy requirements , equal to a water gun fire of consumption, coupled with 20 L / s hydrant water usage. Residential water layer fire not more than 40 L / s. But residential layer spray Standpipe t

8、o set up independently, based in the First Floor Wet alarm valve, hydraulic alarms based on duty nearby. If the nozzle for each five dollars, the </p><p>  For purely residential floor of a high-rise buildin

9、g category, residential elevators and the Office of sidewalk are required to spray for protection, I believe sprinkler system and fire hydrant system is also suitable for fire pump, but adjustments to the fire pump flow,

10、 Additional that is the typical number of nozzles can flow. Taking into account the role of sprinkler system time with the fire hydrant system, the pump should be separately installed pipeline, When the fire time to &quo

11、t;cut off one </p><p>  To maintain the residential elevators and the Office of the beautiful hallway, with no ceiling, use wall-nozzle, Spray deposition pipeline dark wall. Sprinkler system in the top end o

12、f trial should be established valve and pressure gauge. </p><p>  Above, the senior fire protection design, Residential layer spray system can use the fire hydrant system pump, and no up a separate spray pum

13、p, thereby saving investment and reduce the size of the pumping station. When the residential-only elevators and the Office of Public sidewalk installation of sprinkler systems, only a few of each nozzle closed, Spray on

14、ly to the bottom of the standpipe installation of control valves and flow indicator, without the need to set up on each floor. </p><p>  References : </p><p>  [1] GB 50045-1995, fire protection

15、 design of tall buildings norms [S]. </p><p>  高層商住樓消防設計探討</p><p>  在最近幾年廣州市的商住樓設計過程中,遇到的一個新問題是公安消防部門要求對一類高層住宅的電梯廳和公共走道部分設自動噴水滅火系統(tǒng)。過去,設計人員對現(xiàn)行《高層民用建筑設計防火規(guī)范》(GB 50045—1995)(以下簡稱“高規(guī)”)中規(guī)定自動噴水滅火系統(tǒng)設置范

16、圍第7.6.2條的理解是把住宅排除在外的。高層商住樓消防設計的常規(guī)做法一般采用全樓設消火栓滅火系統(tǒng),裙樓和地下室增設自動噴水滅火系統(tǒng)。因此,噴淋泵的揚程選擇是較低的,功率也較小。在實際工程中曾遇到這樣的例子:某幢28層的商住樓在消防驗收時,公安消防部門要求住宅層的電梯和走道增加噴淋系統(tǒng)。為此業(yè)主不得不增加消防噴淋泵,在梯間安裝消防噴淋管道和噴頭。結果不但增加了工程造價,也影響了電梯廳的美觀及工程進度?! 「鶕案咭?guī)”第七章第二節(jié)對消防

17、用水量的規(guī)定可知,一類高層住宅樓的室內消火栓用水量為20 L/s,而一類高層商住樓的室內消火栓用水量為40L/s,二者相差了一倍。以一幢30層 的住宅樓和一幢相同高度的商住樓(24m以下裙樓為商業(yè)用途,其上為住宅)為例,來分析一下它們的火災危險性。對于商住樓的裙樓,如作為商場、餐廳等用途時,由于其裝修豪華,</p><p>  參考文獻: ?。?] GB 50045—1995,高層民用建筑設計防火規(guī)范[S].&

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
  • 5. 眾賞文庫僅提供信息存儲空間,僅對用戶上傳內容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論