1、Accred Qual Assur (2005) 10:208–213 DOI 10.1007/s00769-005-0910-x P R A C T I T I O N E R S R E P O R TMagnus Holmgren Thomas Svensson Erland Johnson Klas JohanssonReflections regarding uncertainty of measurement, on the
2、 results of a Nordic fatigue test interlaboratory comparisonReceived: 20 October 2003 Accepted: 20 August 2004 Published online: 21 April 2005 ? Springer-Verlag 2005M. Holmgren ()) · E. Johnson · K. Johansson S
3、P Swedish National Testing and Research Institute, Box 857, 501 15 Bor?s, Sweden e-mail: magnus.holmgren@sp.se Tel.: +46-33-165007 Fax: +46-33-165010T. Svensson Fraunhofer-Chalmers Research Centre for Industrial Mathemat
4、ics, Box 857, 501 15 Bor?s, SwedenAbstract This paper presents the experiences of calculation and re- porting uncertainty of measurement in fatigue testing. Six Nordic labora- tories performed fatigue tests on steel spec
5、imens. The laboratories also re- ported their results concerning un- certainty of measurement and how they calculated it. The results show large differences in the way the un- certainties of measurement were cal- culated
6、 and reported. No laboratory included the most significant uncer- tainty source, bending stress (due to misalignment of the testing machine, “incorrect” specimens and/or incor- rectly mounted specimens), whencalculating
7、the uncertainty of mea- surement. Several laboratories did not calculate the uncertainty of measure- ment in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM) [1].Keywords Uncertainty of mea
8、surement · Calculation · Report · Fatigue test · Laboratory intercomparisonDefinitions R Stress ratio Fmin/Fmax · F Force (newtons) · A and B Fatigue strength parameters · s and S Stres
9、s (megapascals) · N Number of cyclesIntroductionThe correct or best method of calculating and reporting uncertainty of measurement in testing has been the sub- ject of discussion for many years. The issue became eve
10、n more relevant in connection with the introduction of ISO standards, e.g. ISO17025 [2]. The discussion, as well as implementation of the uncertainty of measurement con- cept, has often been concentrated on which equatio
11、n to use or on administrative handling of the issue. There has been less interest in the technical problem and how to handle uncertainty of measurement in the actual experi- mental situation, and how to learn from the un
12、certainty of measurement calculation when improving the experi- mental technique. One reason for this may be that the accreditation bodies have concentrated on the very exis- tence of uncertainty of measurement calculati
13、ons for an accredited test method, instead of on whether the calcu- lations are performed in a sound technical way. Thepresent investigation emphasises the need for a more technical focus.One testing area where it is dif
14、ficult to do uncertaintyof measurement calculations is fatigue testing. However, there is guidance on how to perform such calculations, e.g. in Refs. [3, 4]. To investigate how uncertainty of measurement calculations are
15、 performed for fatigue tests in real life, UTMIS (the Swedish fatigue network) started an interlaboratory comparison where one of the most essential parts was to calculate and report the uncertainty of measurement of a t
16、ypical fatigue test that could have been ordered by a customer of the participating labora- tories. For cost reasons, customers often ask for a limited number of test specimens but, at the same time, they re- quest a lot
17、 of information about a large portion of the possible stress-life area [from few cycles (high stresses) to millions of cycles (low stresses) and even run-outs]. The way the calculation was made should also be reported. T
18、he outcome concerning the uncertainty of measurement from the project is reported in this article.210glected. The modelling problem was mentioned, but not considered as an uncertainty source. Laboratory 2. The report con
19、tains no uncertainty evaluation. The uncertainties in the load cell and the micrometer are considered, but neglected with refer- ence to the large material scatter. Specimen tempera- ture was measured. Modelling problems
20、 are mentioned by a comment regarding the choice of load levels. Laboratory 3. The report contains no uncertainty evaluation. However, the accuracy of the machine is given and the load was controlled during the tests to
21、be within specified limits. The bending stresses were measured on one specimen, but their influence on the fatigue result was not taken into consideration. Laboratory 4. The uncertainties in the load cell and the dimensi
22、onal measurements are considered in an eval- uation of stress uncertainty. The method for the eval- uation is not in accordance with the GUM method, but was performed by adding absolute errors. The bending stress influen
23、ce and the control system deviations are considered, but not included in the uncertainty evalu- ation. The failure criterion is mentioned and regarded as negligible, and corrosion is mentioned as a possible source of unc
24、ertainty. Laboratory 5. Uncertainties in the load cell and the load control were considered, and the laboratory stated in the report that the evaluation of the load uncertainty was performed according to the CIPM method.
25、Laboratory 6. No report was provided, but only ex- perimental results and a W?hler curve estimate.No laboratory reported the uncertainty in the estimated material properties, the W?hler parameters, but at most the uncert
26、ainty in the applied stress. The overall picture of the uncertainty considerations is that only uncertainty sources that are possible to estimate from calibration re- ports were taken into account in the final evaluation
27、.One important source that several laboratories men-tioned is the bending stresses induced by misalignment in the testing machine, incorrectly mounted test specimens or “incorrect” specimens. The amount of bending stress
28、 was also estimated in some cases, but its influence on the uncertainty in the final W?hler curve was not investi- gated.The results from this experimental investigation showthat there are different ways of determining t
29、he W?hler curve from the experimental result. One problem is the surviving specimens, the run-out results. Four laboratories used only the failed specimens’ results for the curve-fit, one laboratory neglected all results
30、 at the lowest level, and one laboratory included the run-outs in the estima- tion. Another problem is the mathematical procedure for estimating the curve. Common practice, and the recom- mendation in the ASTM standard,
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 眾賞文庫(kù)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映(英文).pdf
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映(英文).pdf
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映.doc
- 外文翻譯--關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映.doc
- 【013】關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映【中文6800字】
- 【013】關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映【中文6800字】
- 【013】關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映【中文6800字】.doc
- 【013】關(guān)于北歐的疲勞實(shí)驗(yàn)室的比較—測(cè)量結(jié)果不確定值的反映【中文6800字】.doc
- 實(shí)驗(yàn)室認(rèn)可中的測(cè)量不確定度評(píng)定.pdf
- 高度卡尺示值誤差測(cè)量結(jié)果的不確定度評(píng)定
- 杠桿表示值誤差測(cè)量結(jié)果不確定度評(píng)定
- 血壓計(jì)示值誤差測(cè)量結(jié)果的測(cè)量不確定度評(píng)定
- 驗(yàn)光鏡片頂焦度值測(cè)量結(jié)果的不確定度評(píng)定
- 絕緣電阻表示值誤差測(cè)量結(jié)果的不確定度評(píng)定
- 空氣焓值法測(cè)量結(jié)果不確定度研究.pdf
- 燃油加油機(jī)示值誤差的測(cè)量結(jié)果擴(kuò)展不確定度
- 工作壓力表示值誤差測(cè)量結(jié)果的不確定度評(píng)定
評(píng)論
0/150
提交評(píng)論