1、過程安全: 如何設計最適合用戶需要的安全系統(tǒng)?,2,Protect People, Environments & AssetsEnhance system safety with flexible, scalable safety solutions Lower costs by deploying an integrated safety architectureObtain maximum availability

2、 and reliability with proven safety technologies Reduce risk by leveraging the knowledge of safety expertsLower troubleshooting time and costs with Intelligent Motor ControlReduce the risks associated with the operati

3、on and maintenance of electrical equipment with safety Motor Control CentersReduce downtime and maintenance costs by protecting rotating assets,Enhancing the Value of Safety,,Key Characteristics and Features of a Safet

4、y Integrity System (SIS),3,Fail SafeorFault Tolerant,SIL Capability,Functional Requirements,Performance,Size,Connectivity,Key features (Benefits),Flexibility,Cost,Safety and Critical Control,Economical risk reduction b

5、y protecting only critical assets,,High Availability Process Control… High availability solutions from redundant I/O to redundant controllers, resilient networks to redundant HMI servers,,Scalable Process Safety

6、… Integrated BPCS and scalable SIS solutions, including TMR for the highest availability,,Process SafetyRecognize RA’s Strength in the Market,5,6,AADvance Core Components,7,ControllerScalability in Size and R

7、edundancy,8,,,,,Flexible Architectures,,,,,,,,I/O backplane,CPU Base/backplane,I/O Backplane,TA,TA,Each input slot group can be configured for simplex (1oo1D), dual (1oo2D) or triplicated (2oo3),Each output slot group ca

8、n be configured for fail-safe (1oo2D) or fault-tolerant (Quad),Controller base allows simplex, dual or triplicated processor configurations and connections to 48 I/O module slots,Portal & Network Scalability & C

9、onnectivity,9,Ethernet based Safety Network,Workstation,portal,Workstation,NAS,Scalable Redundancy Simplex (SIL 2),10,,,,,1oo1D Fail Safe – Certified for use in SIL2 applications,,,,,,,,I/P,CPU,O/P,TA,TA,AADvance Contro

10、ller Simplex,11,,,CPU Base with one CPU populated,I/O Base with one input and one output fail safe,Scalable Redundancy Simplex (SIL3),12,,,,,1oo1D/1oo2D Fail Safe – Certified for use in SIL3 applications,,,,,,,,I/P,CPU

11、,O/P,TA,TA,AADvance Controller Simplex IO, FT CPU,13,,Redundant CPUs,Scalable Redundancy Redundant (SIL3),14,,,,,,,,,,,,I/P,CPU,O/P,TA,TA,1oo2D Fault Tolerant – Certified for use in SIL3 applications,,1oo2D/2oo3 Fault

12、Tolerant – Certified for use in SIL3 applications,AADvance Controller Redundant,15,,,,,Redundant CPUs,Redundant Terminations,Redundant outputs,Redundant inputs,Scalable Redundancy TMR (SIL3),16,,,,,SIL3 TMR Fault Tol

13、erant applications,,,,,,,I/P,CPU,O/P,TA,TA,,AADvance Controller Triplicated,17,Triplicated CPUs,Triplicated Terminations,Fault Tolerant outputs,,,,Triplicated inputs,,,,,,,Input Architecture – Simplex (1oo1D)Input Arch

14、itecture – Dual (1oo2D)Input Architecture – TMR (2oo3D),18,,,,,,,P,H,,PV,HART,TA,I/P Module,Processor,IO Driver,Logic,,4-20mA,4-20mA,,,,P,H,,,,P,H,,,,Output Architecture – Simplex (1oo2D)Output Architecture – Redundant

15、 (QUAD),19,,CMD,Processor,IO Driver,Logic,,,,TA,,O/P Module,,,,24v A,24v B,,,,D,D,A,B,Flexible Architecture Summary,20,Workbench,21,All 5 IEC 61131-3 languages.,WorkbenchRepository,22,Files are stored in a central repo

16、sitory. Multiple people can work on different portions of a project at the same time!,WorkbenchProgram Version Comparison,23,Compare program versions! See what was changed, added & deleted!,,WorkbenchProgram Versio

17、n History,24,The workbench saves all file versions.,WorkbenchProgram Simulation,25,Simulate & test programs offline!,AADvance Workbench,26,AADvance Summary,AADvance Summary,Integrated Control & Safety,29,Rockwel

18、l Automation Safety Solutions,Cost effective approach to risk managementThe right degree of protection and fault tolerance Helps manage Capital and Operating Budgets for from an automation asset perspectiveMigration s

19、trategies & expertiseEnvironmental ComplianceCritical Control Solutions which assure asset integrity Reporting packages to support complianceSolutions to help maintain process boundaries; protecting people, asset

20、s & the environmentFit for Function/Purpose hardware designTake the risk out of applying safety systemsEfficient space requirementsOver 40 years of deploying Safety SolutionsKnowledgeable People including Functi

21、onal Safety ConsultantsSafety expertise to help determine what is needed to operate safetyExpertise to provide the linkage between behavioral safety and process safety,30,Services for a Risk Based Approach,Functional S

22、afety ConsultancyCertified Functional Safety EngineersRisk Based AssessmentManagement IEC 61508 processSIL AssessmentTrainingValidation and Compliance,31,Copyright © 2011 Rockwell Automation, Inc. All rights r

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
  • 5. 眾賞文庫僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論