土木工程施工組織課程設(shè)計(jì)_第1頁(yè)
已閱讀1頁(yè),還剩26頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

1、<p><b>  目錄</b></p><p>  編制依據(jù)···························

2、;···················2</p><p>  工程概括·············

3、;·································3</p><p>

4、;  施工部署···································

5、83;··········5</p><p>  3.1施工部署原則····················

6、3;···············5</p><p>  3.2工程管理目標(biāo)················

7、;····················6</p><p>  施工準(zhǔn)備工作···········

8、83;·····························7</p><p>  4.1.1技術(shù)準(zhǔn)備·

9、3;····································&#

10、183;·8</p><p>  施工方案及施工方法·····························

11、83;·10</p><p>  5.1施工流向和施工順序··························11</p><

12、p>  5.2施工方案選擇··································

13、·12</p><p>  5.3施工方法······························&#

14、183;··········12</p><p>  施工平面布置·····················

15、;···················25</p><p>  施工組織及施工進(jìn)度計(jì)劃···········

16、83;·············26</p><p><b>  1編制依據(jù)</b></p><p> ?。?)規(guī)劃設(shè)計(jì)圖已經(jīng)通過審批;附圖</p><p> ?。?)從化市計(jì)委已經(jīng)下達(dá)“基本建設(shè)計(jì)劃書”;</

17、p><p> ?。?)已經(jīng)委托某勘察設(shè)計(jì)院完成“巖土工程勘察報(bào)告”。</p><p><b>  2 工程概況</b></p><p>  工程名稱:某職工住宅小區(qū)</p><p>  工程地點(diǎn):某中等城市</p><p><b>  設(shè)計(jì)單位:</b></p>&

18、lt;p>  1、該工程為某單位新建的職工住宅小區(qū),每棟住宅樓為3個(gè)單元,5層,每層高3.0米。每單元尺寸為15米*24米??蚣芙Y(jié)構(gòu)。</p><p>  2、工程位于某中等城市,區(qū)內(nèi)地勢(shì)較高,基本不受地下水的影響,全年氣候條件均適宜一般性土建安裝施工。</p><p>  3、小區(qū)位于九江市前進(jìn)東路與青年南路交匯處,區(qū)內(nèi)地勢(shì)平坦,業(yè)主征用土地較多,土建施工臨時(shí)設(shè)施布置場(chǎng)地只在東、南

19、方向前進(jìn)西路路與青年南路約束控制,西、北方向可以較自由安排。</p><p>  4、本工程基礎(chǔ)為鋼筋混凝土獨(dú)立基礎(chǔ)。</p><p>  5、施工所需要的人力、材料及設(shè)備均可以按照要求給予滿足。</p><p>  6、工期要求:施工工期為8~12個(gè)月。</p><p><b>  工程技術(shù)條件</b></p&g

20、t;<p><b>  1、自然條件</b></p><p>  1)溫度:最熱月平均29.6度,最冷月2.2度,夏季極端最高39.8度。冬季極端最低1.0度;</p><p>  2)相對(duì)濕度:最熱月平均75%;</p><p>  3)主導(dǎo)風(fēng)向:全年為西北風(fēng),夏季為東南風(fēng),基本風(fēng)壓W0=300N;</p><

21、;p>  4)基本雪壓:年降雨量1550mm;</p><p><b>  2、工程地質(zhì)條件</b></p><p>  1)自然地表1m內(nèi)為填土,填土下層為3m厚砂質(zhì)粘土。再下為礫石層,砂質(zhì)粘土的允許承載力為230KN/m2。礫石層允許承載力為300-400KN/m2。</p><p>  2)地下水位在地表以下3.0m,無侵蝕性。&l

22、t;/p><p>  3)地震烈度:7度。</p><p><b>  3、材料供應(yīng)</b></p><p>  1)三材由建材公司供應(yīng),品種齊全。</p><p>  2)墻體材料可選用小型混凝土砌塊。</p><p><b>  4、施工條件和能力</b></p>

23、<p>  1)施工單位機(jī)械化程度較高,技術(shù)力量雄厚;</p><p>  2)材料運(yùn)輸條件良好,所有材料均在市區(qū)5公里范圍內(nèi)可以采購(gòu)供應(yīng);</p><p>  3)條件均能滿足施工的要求;</p><p><b>  4)工程施工期限</b></p><p>  本工程擬定于2015年12月5日開工,要求

24、在2016年8月15日竣工,日歷工期為250天。</p><p><b>  3 施工部署</b></p><p><b>  3.1施工部署原則</b></p><p>  本工程中標(biāo)后,將開展創(chuàng)建“文明工地”活動(dòng),主要采取對(duì)建設(shè)工程質(zhì)量、安全生產(chǎn)、文明施工、降低噪音、保護(hù)環(huán)境等一系列的具體要求,我們的口號(hào)是“建精品工程

25、,展我司雄風(fēng)”特制定創(chuàng)建目標(biāo)。</p><p>  3.1.1在空間上的部署原則——立體交叉施工的考慮</p><p>  為了貫徹空間占滿時(shí)間連續(xù)的原則,保證工程按照總控計(jì)劃工期完成,本工程采用主體與二次圍護(hù)結(jié)構(gòu)、主體與裝飾立體交叉施工。</p><p>  3.1.2總施工順序上的部署原則</p><p><b>  1、先地下

26、、后地上</b></p><p>  施工時(shí),應(yīng)先完成管道、管線等地下設(shè)施、土方工程和基礎(chǔ)工程,然后開始地上工程施工。</p><p><b>  2、先主體、后圍護(hù)</b></p><p>  施工時(shí)應(yīng)該先進(jìn)行框架主體施工,然后進(jìn)行圍護(hù)結(jié)構(gòu)施工。</p><p><b>  3、先結(jié)構(gòu)、后裝飾&l

27、t;/b></p><p>  施工時(shí)先進(jìn)行主體結(jié)構(gòu)施工,然后進(jìn)行裝飾工程施工。</p><p><b>  3.2工程管理目標(biāo)</b></p><p>  3.2.1工程管理質(zhì)量目標(biāo)</p><p>  本工程以嚴(yán)格執(zhí)行國(guó)家強(qiáng)制性標(biāo)準(zhǔn)為前提,確保分部分項(xiàng)工程施工達(dá)到設(shè)計(jì)圖紙要求,根據(jù)合同要求,本工程質(zhì)量應(yīng)達(dá)到省級(jí)

28、優(yōu)良工程標(biāo)準(zhǔn),在施工中以省優(yōu)工程質(zhì)量標(biāo)準(zhǔn)組織實(shí)施。</p><p>  本工程總承包范圍為:地基與基礎(chǔ)(含樁基)、主體結(jié)構(gòu)、建筑裝飾裝修、建筑屋面、建筑給水排水及采暖、建筑電氣、通風(fēng)與空調(diào)等7個(gè)分部,其中地基與基礎(chǔ)、主體結(jié)構(gòu)、建筑裝飾裝修、建筑屋面、建筑電氣、建筑給水排水及采暖、通風(fēng)與空調(diào)等7個(gè)分部達(dá)到優(yōu)良,分項(xiàng)優(yōu)良率達(dá)75%,觀感質(zhì)量得分超過88%。</p><p>  所有的設(shè)備安裝、

29、調(diào)試符合有關(guān)驗(yàn)收規(guī)定:竣工資料齊全,一次完成合格率100%。</p><p>  3.2.2工程安全目標(biāo) 施工現(xiàn)場(chǎng)始終貫徹“安全第一、預(yù)防為主”為指導(dǎo)思想,堅(jiān)持將安全生產(chǎn)責(zé)任制落實(shí)到每一個(gè)生產(chǎn)環(huán)節(jié)中,努力創(chuàng)造安全、文明的良好工作環(huán)境。1.因工死亡事故為零,重大設(shè)備事故為零,火災(zāi)事故為零;2.因工重傷率控制在0.3‰以內(nèi);因工輕傷率控制在1‰以內(nèi);3.一般隱患整改率達(dá)95%,重大隱患整改率達(dá)100%;

30、4.工地按《建筑施工安全檢查標(biāo)準(zhǔn)》檢查項(xiàng)目合格率達(dá)到100%,其中優(yōu)良率達(dá)到70%;5.勞動(dòng)衛(wèi)生(塵、毒、噪聲等有害因素)粉塵作業(yè)點(diǎn)合格率80%以上,毒物作業(yè)點(diǎn)合格率85%以上,物理因素作業(yè)點(diǎn)合格率80%以上。有害因素作業(yè)點(diǎn)隨時(shí)接受上級(jí)部門監(jiān)測(cè);6.創(chuàng)安全合格班組率達(dá)90%以上。3.2.3工程工期目標(biāo) 根據(jù)《建設(shè)工程施工合同》的要求,本工程工期為250日歷天。 本工程擬定于2015年12月5日開工,要求在2016年8月1

31、5日竣工,日歷工期為250天。</p><p>  3.2.4主要分部項(xiàng)的劃分</p><p>  工程施工分為:基礎(chǔ)工程;主體工程;屋面工程;裝修裝飾工程。</p><p>  3.2.5施工總體安排</p><p> ?。?)基礎(chǔ)工程施工程序</p><p>  開挖機(jī)械土方→混凝土墊層→綁扎基礎(chǔ)鋼筋→支基礎(chǔ)模板→

32、基礎(chǔ)混凝土→回填土</p><p>  (2)主體框架結(jié)構(gòu)施工順序:</p><p>  柱子鋼筋→柱、梁、板模板→柱混凝土→綁扎梁板鋼筋→澆筑梁板混凝土→拆?!鲋⌒推鰤K墻</p><p><b>  (3)砌體工程</b></p><p>  砌體工程在經(jīng)技術(shù)負(fù)責(zé)人批準(zhǔn)底層框架拆模后,即可插入進(jìn)行,緊跟主體由下而上

33、逐層施工。</p><p><b>  (4)屋面工程</b></p><p>  屋面防水工程待屋面層結(jié)構(gòu)達(dá)到設(shè)計(jì)強(qiáng)度拆模模版后方可進(jìn)行,屋面防水工程分找平層、隔熱層、防水層等工序。</p><p><b> ?。?)裝修裝飾工程</b></p><p>  裝修裝飾工程先進(jìn)行地面墊層的裝修,再進(jìn)

34、行天棚內(nèi)墻的抹灰,接著做樓地面和樓梯地磚,鋁合金門窗的安裝,最后進(jìn)行外墻涂料的裝飾。</p><p><b>  4施工準(zhǔn)備工作</b></p><p>  4.1.1技術(shù)準(zhǔn)備 </p><p>  1、組織學(xué)習(xí)圖紙,進(jìn)行會(huì)審 </p><p>  通過學(xué)習(xí)圖紙,熟悉圖紙內(nèi)容,了解設(shè)計(jì)要求和施工達(dá)到的標(biāo)準(zhǔn),明確工藝流程

35、,掌握和了解設(shè)計(jì)圖紙細(xì)節(jié)。由建設(shè)單位、設(shè)計(jì)單位、土建、監(jiān)理單位人員共同進(jìn)行圖紙會(huì)審,徹底將施工圖紙所存在的問題消除在施工之前。 </p><p>  2、編制施工方案、預(yù)算、加工計(jì)劃、進(jìn)度計(jì)劃、資金使用計(jì)劃。 </p><p>  施工方案是統(tǒng)籌規(guī)劃該工程進(jìn)行施工準(zhǔn)備和正常施工的全面性技術(shù)經(jīng)濟(jì)文件,同時(shí)也是編制施工圖預(yù)算以保證施工順利進(jìn)行的先行技術(shù)文件之一,是施工交叉搭接、流水順暢進(jìn)行

36、的先決步驟,作好施工前的預(yù)算、加工、進(jìn)度計(jì)劃步驟安排,方可保證原材料、半成品、成品構(gòu)件等按時(shí)進(jìn)場(chǎng)待用。 </p><p>  4.1.2施工組織準(zhǔn)備 </p><p>  該工程采取公司領(lǐng)導(dǎo)下的項(xiàng)目經(jīng)理責(zé)任制的形式組織施工,由公司所屬優(yōu)秀項(xiàng)目經(jīng)理、具有房屋建筑工程豐富施工經(jīng)驗(yàn)的項(xiàng)目經(jīng)理部班子承擔(dān)施工。 </p><p>  項(xiàng)目班子職能部門齊全,包括技術(shù)、現(xiàn)場(chǎng)工長(zhǎng)

37、管理、質(zhì)量、安全、材料、預(yù)算、財(cái)務(wù)、勞資、機(jī)械、治安、后勤等,對(duì)工程施工進(jìn)行全面全過程的系統(tǒng)管理。</p><p>  (1)審查設(shè)計(jì)圖紙,核對(duì)平面尺寸和坑底標(biāo)高,摸清地下構(gòu)筑物及地下管線分布情況,與甲方確認(rèn)。</p><p>  (2)現(xiàn)場(chǎng)工程定位放線工作已完成,場(chǎng)區(qū)內(nèi)的控制網(wǎng)點(diǎn)已設(shè)立,且不受土方開挖的影響。</p><p>  (3)開挖邊線已用白灰撒好,其范圍

38、內(nèi)的障礙物不影響土方開挖。</p><p>  4.1.3施工場(chǎng)地的準(zhǔn)備 </p><p>  本工程施工現(xiàn)場(chǎng)有大量土堆,開工前需做好場(chǎng)地的三通一平工作,組織施工機(jī)械對(duì)場(chǎng)地進(jìn)行平整,對(duì)土方進(jìn)行清運(yùn)。根據(jù)施工總平面布置圖搭建臨時(shí)設(shè)施,修建施工給排水系統(tǒng),搭設(shè)動(dòng)力照明用電系統(tǒng)。為施工作業(yè)和標(biāo)準(zhǔn)化工地的建設(shè)打下良好基礎(chǔ)。 </p><p><b>  4.1

39、.4施工測(cè)量</b></p><p> ?。?)熟悉、校核施工圖軸線尺寸、結(jié)構(gòu)尺寸和各層各部位的標(biāo)高變化及其相互間的關(guān)系。 </p><p> ?。?)對(duì)照總圖,現(xiàn)場(chǎng)勘察、校測(cè)建筑用地紅線樁點(diǎn)、坐標(biāo)、高程及相鄰建筑</p><p>  (3)測(cè)量?jī)x器準(zhǔn)備:光學(xué)經(jīng)緯儀(DJ2)一臺(tái);水準(zhǔn)儀(DS1)一臺(tái);50 m鋼卷尺3個(gè)。以上測(cè)量?jī)x器均應(yīng)在施工前檢定合格

40、,確保測(cè)量數(shù)據(jù)的準(zhǔn)確。 </p><p> ?。?)測(cè)量人員配備:測(cè)量工2~3人,驗(yàn)線員1人,上述人員均持有上崗證書。</p><p>  4.1.5結(jié)構(gòu)施工測(cè)量</p><p>  結(jié)構(gòu)豎向投測(cè):工程采用激光經(jīng)緯儀天頂內(nèi)控法進(jìn)行豎向投測(cè)。</p><p>  施工層放線:放線前應(yīng)在平面上校核軸線,閉合后測(cè)設(shè)細(xì)部軸線,后以此為準(zhǔn)測(cè)量墻和洞口的

41、邊線。</p><p>  高程的豎向傳遞:工程結(jié)構(gòu)施工時(shí),設(shè)六個(gè)標(biāo)高傳遞點(diǎn)分別向上進(jìn)行傳遞,以保證在各流水階段施工層上附近有三個(gè)標(biāo)高點(diǎn),進(jìn)行互相校核。</p><p>  4.1.6建筑物定位放線</p><p>  (1)因本工程在進(jìn)行土方開挖施工時(shí)已由原施工單位進(jìn)行了定位放線及高程控制樁的建立,進(jìn)場(chǎng)后應(yīng)認(rèn)真進(jìn)行復(fù)核,做好原始記錄,驗(yàn)線人復(fù)查合格后報(bào)工程監(jiān)理查驗(yàn)

42、。 </p><p> ?。?)依據(jù)本工程定位和高程點(diǎn),建立本工程軸線控制網(wǎng)和相對(duì)高程控制網(wǎng),具體位置、尺寸、數(shù)量。軸線控制樁點(diǎn)按流水段的劃分設(shè)置。 </p><p>  (3)經(jīng)緯儀觀測(cè)采用正倒鏡取中定點(diǎn),水準(zhǔn)儀測(cè)量采用往返閉合測(cè)量方法,誤差小于等于1.5 mm。距離丈量采用同一把鋼尺往返丈量一次,拉力為50 N丈量結(jié)果當(dāng)中應(yīng)加入尺寸、溫度、拉力、傾斜等改正數(shù)。</p>&

43、lt;p>  (4)軸線控制網(wǎng)的精度要求。根據(jù)規(guī)定本工程布網(wǎng)精度為二級(jí),其中測(cè)角中誤差±12?,邊長(zhǎng)相對(duì)中誤差1/15000。 </p><p>  (5)軸線控制網(wǎng)和高程控制網(wǎng)建立后,驗(yàn)線員進(jìn)行復(fù)核合格后報(bào)工程監(jiān)理查驗(yàn)。</p><p><b>  4.1.7沉降觀測(cè)</b></p><p>  沉降觀測(cè)點(diǎn)的平面位置按設(shè)計(jì)圖

44、紙,在主體結(jié)構(gòu)施工過程中,應(yīng)專人定期觀測(cè),每施工二層觀測(cè)一次。施工完畢后一年內(nèi),每隔三至六個(gè)月觀測(cè)一次,以后每隔六至十二個(gè)月觀測(cè)一次,直至沉降穩(wěn)定。</p><p>  4.1.8非周期性觀測(cè):</p><p> ?。?)基礎(chǔ)混凝土澆筑、回填土施工后觀測(cè)一次。</p><p> ?。?)大量降水、積水后觀測(cè)一次。</p><p> ?。?)出

45、現(xiàn)特殊情況時(shí),依據(jù)情況增加觀測(cè)次數(shù)。</p><p>  (4)施工期間因故停工三個(gè)月以上,停工前和復(fù)工前進(jìn)行觀測(cè)。</p><p>  4 .1.9 塔吊沉降觀測(cè):</p><p>  (1)在雨季來臨前觀測(cè)一次。</p><p>  (2) 雨季后觀測(cè)一次。</p><p>  (3)雨季中及雨后觀測(cè)一次。<

46、/p><p>  5施工方案及施工方法</p><p>  選擇施工方案的基本要求是:①切實(shí)可行;②施工期限滿足合同要求;③確保工程質(zhì)量和施工安全;④施工費(fèi)用最低。</p><p>  5.1施工流向和施工順序</p><p>  5.1.1確定施工起點(diǎn)流向</p><p>  施工起點(diǎn)流向的確定是確定單位工程在平面上或空

47、間上施工的起點(diǎn)的部位和施工進(jìn)行的方向。</p><p>  5.1.2劃分施工段</p><p>  按建筑物的結(jié)構(gòu)層將工程劃分為五個(gè)施工層。</p><p>  5.1.3確定施工方向</p><p>  平面方向施工為Ⅰ段→Ⅱ段,垂直方向?yàn)橐粚印印龑印膶印鍖印?lt;/p><p><b>  5.1

48、.4施工階段</b></p><p>  分為三個(gè)階段:基礎(chǔ)工程→主體工程(一層、二層、三層、四層、五層)→裝飾工程(一層、二層、三層、四層、五層)。</p><p>  5.1.5確定施工順序</p><p>  施工順序是指分部工程中的分項(xiàng)工程或工序之間的先后順序。其中,有一些分項(xiàng)工程或工序的先后順序由于工藝的要求一般固定不變;另外有一些分項(xiàng)工程或工

49、序,其施工的先后不受工藝的限制,而有很大的靈活性。</p><p>  1.基礎(chǔ)工程施工順序</p><p>  測(cè)量放線→機(jī)械開挖→人工修理土→打PHC樁→澆混凝土墊層→扎基礎(chǔ)鋼筋→支基礎(chǔ)模板→澆基礎(chǔ)混凝土→拆模→回填土。施工時(shí),應(yīng)注意排水,以免影響施工進(jìn)度;而且,墊層施工完后,一定要留有技術(shù)間歇時(shí)間,使其有一定強(qiáng)度后,再進(jìn)行下一道工序的施工。</p><p> 

50、 2.主體工程施工順序</p><p>  一層主體結(jié)構(gòu)→ 二層主體結(jié)構(gòu)→ 三層主體結(jié)構(gòu)→ 四層主體結(jié)構(gòu)→ 五層主體結(jié)構(gòu),其中每一層又可以分為:柱筋→柱模板→澆筑柱混凝土→粱、板模板→粱、板鋼筋→澆筑梁、板混凝土→養(yǎng)護(hù)→ 拆模。腳手架的搭設(shè)應(yīng)配合主體結(jié)構(gòu)進(jìn)行。</p><p>  3.屋面及裝飾工程施工順序</p><p>  屋面工程:結(jié)構(gòu)層→找平層→防水層→隔熱

51、層→保護(hù)層。屋面工程與室內(nèi)裝飾工程平行施工,但要注意確保工程質(zhì)量和施工安全,屋面的滲漏無保證時(shí)不能施工裝飾工程。</p><p>  主體結(jié)構(gòu)工程完成通過結(jié)構(gòu)驗(yàn)收后,開始施工裝飾工程。因該工程施工層少,所以裝飾工程的施工順序采用先室外后室內(nèi)的施工順序,先進(jìn)行室外裝飾的同時(shí),拆除腳手架,及時(shí)堵好墻上的腳手孔,也可以保證室內(nèi)裝飾的質(zhì)量,加快腳手架的周轉(zhuǎn)使用。室內(nèi)裝飾采用自上而下的施工順序,這樣做的優(yōu)點(diǎn)是可防止雨水滲漏

52、,保證室內(nèi)裝飾抹灰的施工質(zhì)量。</p><p>  同一層的施工順序?yàn)椋?天棚→ 墻面→樓地面,這樣做的優(yōu)點(diǎn)是地面質(zhì)量容易保證,便于收集落地面、墻面的落地灰,節(jié)約材料,缺點(diǎn)是地面需要養(yǎng)護(hù)時(shí)間和保護(hù)措施,影響工期。</p><p>  樓梯和過道是施工運(yùn)輸材料的主要通道,它們?cè)谑覂?nèi)抹灰完成以后,再自上而下施工,室內(nèi)抹灰全部完成以后,進(jìn)行門窗扇的安裝。</p><p>

53、<b>  5.2施工方案選擇</b></p><p>  5.2.1運(yùn)輸系統(tǒng)的選擇</p><p>  采用施工電梯及汽車組成場(chǎng)內(nèi)水平、垂直運(yùn)輸系統(tǒng),場(chǎng)內(nèi)小型材料水平運(yùn)輸采用小翻斗車和手推車。</p><p><b>  5.2.2基礎(chǔ)施工</b></p><p>  土方工程采用機(jī)械開挖,機(jī)械裝

54、運(yùn)出場(chǎng)棄置;</p><p>  5.2.3鋼筋砼結(jié)構(gòu)施工</p><p>  1.本工程鋼筋由公司加工廠制作加工,運(yùn)到現(xiàn)場(chǎng)綁扎,部分由現(xiàn)場(chǎng)加工,根據(jù)設(shè)計(jì)要求框架柱角筋直徑≤25采用綁扎搭接接頭,其余柱筋及梁鋼筋d≥22 采用螺紋套筒接頭, d<22采用焊接接頭。</p><p><b>  2.模板工程</b></p><

55、p>  1、模板均采用18厚,防水膠膠合板散裝散拼,50×100 的木枋作背楞。 </p><p>  2、梁板起拱按規(guī)范執(zhí)行。</p><p><b>  3.砼工程</b></p><p>  采用商品混凝土,由攪拌廠攪拌運(yùn)到工地泵送。</p><p><b>  5.2

56、.4砌體施工</b></p><p>  1、砌體工程在主體框架結(jié)構(gòu)驗(yàn)收合格后開始。</p><p>  2、現(xiàn)場(chǎng)設(shè)自動(dòng)計(jì)量砂漿攪拌站集中攪拌,手推車水平運(yùn)輸,施工電梯垂直運(yùn)輸。</p><p>  5.2.5腳手架施工</p><p>  外架采用鋼管腳手架加綠色密封安全網(wǎng)封閉施工。</p><p>  

57、5.2.6安裝工程施工</p><p>  安裝工程施工包括給排水工程,動(dòng)力及照明工程,通風(fēng)空調(diào)等,主要按各工種的施工特點(diǎn),重點(diǎn)強(qiáng)調(diào)必須加強(qiáng)預(yù)埋、預(yù)留工作和設(shè)備吊裝就位的施工。</p><p>  5.2.7裝修工程施工</p><p>  本工程裝修施工前,先做樣板間、樣板墻,經(jīng)業(yè)主、設(shè)計(jì)、監(jiān)理,施工四方認(rèn)可后方能大面積施工。樓層采用由下而上,外墻裝飾裝修采用由上

58、而下的施工方法,在裝飾裝修中注意成品保護(hù)。</p><p>  5.2.8室外總平及道路</p><p>  配專業(yè)測(cè)量人員和先進(jìn)的施工機(jī)械,嚴(yán)格按照設(shè)計(jì)施工。</p><p><b>  5.3施工方法</b></p><p>  5.3.1 測(cè)量定位1.平面控制 根據(jù)本工程設(shè)計(jì)圖紙,結(jié)合實(shí)地的施工情況要求,

59、建立工程的方格控制網(wǎng),作為該建筑物的軸線控制。方格網(wǎng)精度要求控制在1/15000,各建筑物精度要求控制在1/10000。</p><p>  2.高程控制(1)以業(yè)主提供的城市水準(zhǔn)點(diǎn)高程經(jīng)復(fù)核作為引測(cè)的依據(jù)。(2)高程引測(cè):現(xiàn)場(chǎng)設(shè)施工期間臨時(shí)小準(zhǔn)點(diǎn)三個(gè),一個(gè)為永久水準(zhǔn)點(diǎn),離建筑物50m以外,水準(zhǔn)測(cè)量的容許誤差按國(guó)家測(cè)量規(guī)范二等水準(zhǔn)測(cè)量標(biāo)準(zhǔn)。3.建筑物層高控制:按水準(zhǔn)測(cè)量與鋼尺量距相結(jié)合的方法進(jìn)行,即在建筑

60、物設(shè)置二個(gè)高程控制點(diǎn),其高程從水準(zhǔn)點(diǎn)用水準(zhǔn)儀引測(cè)后,以后各層高程由這二點(diǎn)用鋼尺丈量使用,其中一點(diǎn)作為校核用。4.沉降觀測(cè):自地基基礎(chǔ)完成至工程竣工,每施工一層測(cè)一次,有特殊情況另加強(qiáng)觀測(cè)。觀測(cè)人員使用儀器設(shè)備水準(zhǔn)儀要固定,按規(guī)定的日期、方法、路線進(jìn)行觀測(cè)。5.測(cè)量工程由專業(yè)人員負(fù)責(zé),儀器設(shè)備按工程技術(shù)要求選用,且經(jīng)具有資質(zhì)計(jì)量部門檢定合格,測(cè)量作業(yè)前還要自檢校正,合格后方可使用,測(cè)量操作方法符合規(guī)范規(guī)定。6.測(cè)量定位點(diǎn)的定期校核:

61、軸線控制點(diǎn)每隔一周校核一次,龍門架上的軸線控制網(wǎng)三天校核一次,以確保建筑物定位放樣的精確性。7.建筑物垂直度控制:工程測(cè)量規(guī)范要求分層豎向軸線偏差為±5mm,豎向軸線的垂直偏差為±20mm且≤H/1000。每層軸線施測(cè)采用“外控法”及“內(nèi)控法”相結(jié)合,用經(jīng)緯儀或鉛錘從底部基準(zhǔn)點(diǎn)引至</p><p> ?。?)用白鐵皮做一高度為1000mm的錐形漏斗,CGM高強(qiáng)、無收縮灌漿料從漏斗中灌入。預(yù)

62、埋鋼板四周用一角鋼做成的圓弧形框模,上面用鋼筋卡具固定。由于CGM灌漿料具有高強(qiáng)、無收縮、免振搗、微膨脹、自流、自密實(shí)的特性,因此避免了用振搗棒振動(dòng)而引起預(yù)埋件位移,確保了預(yù)埋件定位的精確性。</p><p>  2.豎向預(yù)埋件的精確定位</p><p>  為確保豎向預(yù)埋鐵件的精確定位,在預(yù)埋鐵件和錨筋相反的鋼板面上焊接四個(gè)螺桿,并在、柱側(cè)模上定出預(yù)埋件的精確定位及四個(gè)螺桿的位置,然后用

63、鉆孔機(jī)在模板上鉆出四個(gè)螺桿的位置,合柱模時(shí),將掛有預(yù)埋件的模板先合上,再將預(yù)埋件的錨筋和柱主筋點(diǎn)焊固定,同時(shí)在柱模的外側(cè)用四個(gè)螺母將預(yù)埋件固定。并加強(qiáng)柱模的整體剛度,將強(qiáng)模撐設(shè)置,由于砼澆搗時(shí),模板的位移相對(duì)較小,因此可確保豎向預(yù)埋件的精確定位。</p><p><b>  5.3.2基礎(chǔ)工程</b></p><p>  1. PHC樁施工工藝:插樁→錘打→接樁→送樁

64、。</p><p>  插樁:樁打入過程中修正樁的角度較困難,因此就位時(shí)應(yīng)正確安放。第一節(jié)管樁插入地下時(shí),要盡量保持位置方向正確。開始要輕輕打下,認(rèn)真檢查,若有偏差應(yīng)及時(shí)糾正,必要時(shí)要拔出重打。校核樁的垂直度可采用垂直角,即用兩個(gè)方向(互成90°)的經(jīng)緯儀使導(dǎo)架保持垂直。通過樁機(jī)導(dǎo)架的旋轉(zhuǎn)、滑動(dòng)及停留進(jìn)行調(diào)整。經(jīng)緯儀應(yīng)設(shè)置在不受打樁影響處,并經(jīng)常加以調(diào)平,使之保持垂直。</p><p

65、>  錘打:因地層較軟,初打時(shí)可能下沉量較大,宜采取低提錘,輕打下,隨著沉樁加深,沉速減慢,起錘高度可漸增。在整個(gè)打樁過程中,要使樁錘、樁帽、樁身盡量保持在同一軸線上。必要時(shí)應(yīng)將樁錘及樁架導(dǎo)桿方向按樁身方向調(diào)整。要注意盡量不使管樁受到偏心錘打,以免管樁受彎受權(quán)。打樁較難下沉?xí)r,要檢查落錘有無傾斜偏心,特別是要檢查樁墊樁帽是否合適。如果不合適,需更換或補(bǔ)充軟墊。每根樁宜連續(xù)一次打完,不要中斷,以免難以繼續(xù)打下。</p>

66、<p>  接樁:接樁時(shí)要注意新接樁節(jié)與原樁節(jié)的軸線一致,兩施焊面上的泥土、油污、鐵銹等要預(yù)先清刷干凈。當(dāng)下節(jié)樁的樁頭距地面1—1.2m時(shí),即可進(jìn)行焊接接樁。接樁時(shí)可在下節(jié)樁頭上安裝導(dǎo)向箍,以便新接樁節(jié)的引導(dǎo)就位。上節(jié)樁找正方向后,對(duì)稱點(diǎn)焊4—6點(diǎn)加以固定,然后拆除導(dǎo)向箍。管樁焊接施工應(yīng)由有經(jīng)驗(yàn)的焊工按照技術(shù)規(guī)程的要求認(rèn)真進(jìn)行。</p><p>  送樁:為將管樁打到設(shè)計(jì)標(biāo)高,需要采用送樁器,送樁器用

67、鋼板制作,長(zhǎng)4m。設(shè)計(jì)送樁器的原則是打入阻力不能太大,容易拔出,能將沖擊力有效地傳到樁上,并能重復(fù)使用。</p><p><b>  2.樁承臺(tái)施工</b></p><p>  樁承臺(tái)混凝土,基礎(chǔ)梁混凝土均采用C30。</p><p>  所有樁承臺(tái)頂標(biāo)高=-1.0m,樁承臺(tái)高H=800mm,PHC樁頂嵌入承臺(tái)尺寸100mm,嵌入部分及與承臺(tái)接

68、觸的樁周打毛,樁內(nèi)鋼筋呈傘形錨入承臺(tái)內(nèi)長(zhǎng)度≥35d及800mm。</p><p>  承臺(tái)基礎(chǔ)施工順序:基礎(chǔ)墊層施工→鑿除樁頂松散混凝土→承臺(tái)側(cè)模安裝→承臺(tái)鋼筋施工→混凝土澆筑→模板拆除→土方回填。</p><p><b>  3.土方回填</b></p><p>  ①基坑回填在基礎(chǔ)短柱施工完畢且驗(yàn)收合格后,立即進(jìn)行。在地基梁施工完畢可進(jìn)行地

69、坪回填土的施工,亦可在一層結(jié)構(gòu)施工完畢后進(jìn)行地坪的回填工作。</p><p>  ②基坑回填前需清除基坑內(nèi)雜物,抽除基坑內(nèi)積水。</p><p> ?、刍靥畹耐临|(zhì)應(yīng)符合設(shè)計(jì)要求?;靥钔羶?nèi)不得有石塊、碎磚、灰渣、及有機(jī)雜物?;靥钔另毞謱雍粚?shí),每層不超過厚度≤250㎜,機(jī)械夯實(shí)分層厚度≤300㎜。經(jīng)過分層夯實(shí)和碾壓。填土?xí)r應(yīng)控制最優(yōu)含水率,按擊實(shí)試驗(yàn)確定最優(yōu)含水量與相應(yīng)的最大干密度。填土應(yīng)均勻

70、密實(shí),壓實(shí)系數(shù)不小于0.93。</p><p><b>  5.3.3主體工程</b></p><p>  本工程長(zhǎng)66.9m,最大寬度為14.7m,高13.2。采用施工電梯2臺(tái)。</p><p><b>  1.腳手架工程</b></p><p>  主要采用扣件式鋼管腳手架,與竹排相結(jié)合,鋼管起

71、支撐作用,竹排方便行走。</p><p>  扣件式鋼管腳手架的搭設(shè)工藝流程如下:基礎(chǔ)準(zhǔn)備→安放墊板→安放底座→豎立管并同時(shí)安掃地桿→搭設(shè)水平桿→搭設(shè)剪刀撐→鋪腳手板→搭擋腳板和欄桿。</p><p>  扣件式鋼管腳手架搭設(shè)要求:</p><p> ?、俨捎忙?8鋼管,壁厚3.5㎜,禁止使用嚴(yán)重銹蝕的鋼管??奂缬辛芽p、變形則禁止使用。</p>&l

72、t;p> ?、诹U基礎(chǔ)地面應(yīng)平整、夯實(shí),不積水。立桿下應(yīng)架墊木塊,相鄰兩根立桿接頭應(yīng)錯(cuò)開50㎝以上。橫向間距1.05m左右。垂直度允許偏差在1/200以內(nèi)。</p><p>  ③小橫桿里端伸出內(nèi)立桿15~35㎝,離墻5~15㎝,外端伸出外立桿10㎝以上。</p><p> ?、艽髾M桿應(yīng)設(shè)四根,同步架同跨不超過2個(gè)接頭,高1.7~1.8m。</p><p> 

73、?、菁舻稉味揭陨霞艿膬啥撕椭虚g每隔15m應(yīng)自下而上設(shè)置。應(yīng)與地面成45~60度夾角,兩桿相交處應(yīng)用扣件扣緊。兩桿搭接接頭40㎝,用2只扣件扣緊,最下一對(duì),與立桿連接點(diǎn)距地面不宜大于50㎝。</p><p> ?、捱B墻桿拉接點(diǎn)預(yù)埋件: 每層在梁板砼施工時(shí)應(yīng)預(yù)埋Φ48鋼管,預(yù)埋時(shí)鋼管深埋入梁底,露出梁面30㎝左右,橫向間距4.5㎝左右,上下呈錯(cuò)位設(shè)置。</p><p> ?、邫跅U:每步架必須

74、設(shè)置1m高防護(hù)欄桿。</p><p> ?、嗫奂陌惭b:用于連接大橫桿的對(duì)接扣件,開口應(yīng)朝架子內(nèi)側(cè),螺栓向上避免開口朝上,裝螺栓時(shí)應(yīng)注意將根部放正,保持技術(shù)擰緊程度,當(dāng)扣件夾緊鋼筋時(shí),開口處的最小距離應(yīng)不小于5㎜。</p><p> ?、嶂癜势匿佋O(shè):操作層及其下一皮架應(yīng)滿鋪,里立桿離墻間距>20㎝處每四步設(shè)一道防護(hù)。竹笆片長(zhǎng)向鋪設(shè),竹笆片之間需相互搭接,搭接長(zhǎng)度15~20㎝不得空鋪

75、,不得鋪深頭板(所有竹笆片下均須有兩根以上的大橫桿),竹笆片應(yīng)用18號(hào)的鐵絲同鋼桿扎牢,竹笆片離墻面不得大于35㎝。</p><p><b> ?、獍踩W(wǎng)的掛設(shè):</b></p><p>  安全網(wǎng)采用密目式安全立網(wǎng),選購(gòu)安全立網(wǎng)時(shí),應(yīng)選擇省建委推薦的合格安全網(wǎng),安全網(wǎng)附掛于立桿處,四周之間相互連接并與立桿、拉桿、大橫桿相連接。安全網(wǎng)搭設(shè)要封閉,不得有空隙,要張拉緊,

76、不皺折,除去安全信道口處,其余地方凡有架體處均封閉張拉,當(dāng)架體搭設(shè)高度超過兩個(gè)架高度時(shí),即可掛設(shè)安全網(wǎng)。</p><p><b>  腳手架的驗(yàn)收內(nèi)容:</b></p><p> ?、偌茏拥牟贾茫毫U、大、小橫桿間距。</p><p> ?、诩茏拥拇钤O(shè)和組裝。</p><p> ?、圻B墻點(diǎn)式與結(jié)構(gòu)固定部分是否安全可靠;剪

77、力撐、斜撐是否符合要求。</p><p> ?、苤癜势匿佋O(shè)和密目網(wǎng)的掛設(shè)是否符合要求。</p><p>  腳手架拆除順序應(yīng)是后搭設(shè)的部件先拆,先搭設(shè)的部件后拆,嚴(yán)禁采用推倒或拉倒的拆除做法,并且拆除的腳手架部件應(yīng)及時(shí)運(yùn)至地面,嚴(yán)禁從空中拋擲。</p><p><b>  腳手架的使用:</b></p><p>  ①

78、腳手架搭設(shè)完畢經(jīng)項(xiàng)目部驗(yàn)收合格簽章后方可使用,使用中嚴(yán)禁在架體上使用集中荷載,腳手架上每平方米負(fù)載不得超過200㎏,使用中如發(fā)現(xiàn)腳手架異常情況應(yīng)及時(shí)上報(bào)安全員或施工員,及時(shí)整修。</p><p> ?、谠谀_手架使用中,須定期組織檢查,須做到使用中架體保持完整。</p><p> ?、凼褂媚_手架時(shí),不得在腳手架上打鬧,往下拋物體,施工人員不得將腳手架當(dāng)做垂直運(yùn)輸工具隨意爬上爬下。</p

79、><p><b>  架子的拆除:</b></p><p> ?、俦竟こ掏饧懿鸪殱M足施工需要,并經(jīng)技術(shù)負(fù)責(zé)人同意后方可拆除。</p><p>  ②架子拆除時(shí)應(yīng)劃分作業(yè)區(qū),周圍設(shè)圍欄或豎向警戒標(biāo)志,地面應(yīng)有專人指揮,嚴(yán)禁非作業(yè)人員入內(nèi)。</p><p> ?、鄄鸪樞驊?yīng)遵循由上而下,先搭后拆,后搭先拆的原則。即先拆欄桿、腳

80、手板、剪刀撐、斜撐,后拆小橫桿、大橫桿、立桿等,并按一步一清的原則依次進(jìn)行,要嚴(yán)禁上下同時(shí)拆除作業(yè)。</p><p> ?、懿鹆U時(shí)應(yīng)先抱住立桿再拆開最后兩個(gè)扣,拆除大橫桿、斜撐、剪刀撐。</p><p>  腳手架施工中的注意事項(xiàng):</p><p> ?、倌_手架的施工人員必須持證上崗。</p><p> ?、谑┕と藛T在搭設(shè)或拆除腳手架前必須

81、經(jīng)過檢查,身體不適、疾病、恐高癥者不得上崗。</p><p> ?、鄞钤O(shè)或拆除腳手架時(shí),施工人員應(yīng)處于精神良好狀態(tài),不酗酒、不熬夜、思維清晰。</p><p> ?、艽钤O(shè)或拆除腳手架時(shí),不得光腳,不得穿易滑鞋、拖鞋上下施工。</p><p> ?、萦晏臁⒗滋旒捌呒?jí)以上大風(fēng)時(shí)不得進(jìn)行搭設(shè)或拆除腳手架。</p><p>  ⑥夜間不得進(jìn)行搭設(shè)或拆

82、除腳手架,夜間使用腳手架必須經(jīng)過技術(shù)人員同意,同時(shí)有足夠的照明。</p><p> ?、叽钤O(shè)或拆除腳手架應(yīng)嚴(yán)格遵守本方案及有關(guān)安全管理制度,不倒序施工,不野蠻施工。</p><p><b>  5.3.4模板工程</b></p><p>  本工程全部用用木模板,模板支撐采用木塊排架支撐。具體包括樁承臺(tái)模板、柱模板、梁模板、樓板模板。</

83、p><p> ?、僦0澹褐0迨┕げ捎谜w預(yù)拼裝的方法。即預(yù)先將柱模板安裝成形,在吊裝前,先檢查已經(jīng)整體預(yù)組拼的模板上、下口對(duì)角線的偏差及連接件、柱箍等的牢固程度,檢查鋼筋是否有礙柱模的安裝,并用鉛絲將柱頂鋼筋先綁扎在一起,以利柱模從頂部套入。待整體預(yù)組拼模板吊裝就位后,立即用四根支撐或有花籃螺絲的纜風(fēng)繩與柱頂四角拉結(jié),并校正其中心線和偏斜,全面檢查合格后,再群體固定。</p><p>  

84、②梁模板:梁截面尺寸較多,采用較靈活的木模板。模板支撐采用碗扣件式鋼管滿堂腳手架進(jìn)行支撐,底模與側(cè)模間用連接角模連接,側(cè)模頂部用陰角模與樓板模板相連。</p><p>  懸臂梁按0.5%起拱,起拱高度不小于20,跨度≥7m的二端支承梁按0.3%起拱, 懸臂構(gòu)件的支撐必須待混凝土強(qiáng)度達(dá)到100%,且上部結(jié)構(gòu)完成一層后方可拆除支撐。</p><p> ?、蹣前迥0澹簶前迥0宀捎媚z合板模板。樓

85、板模板的支撐架子采用碗扣件式滿堂腳手架支撐,膠合板模板面板應(yīng)涂刷脫模劑,以利于脫模,膠合板模板的接頭應(yīng)平整,接頭處可用膠帶紙粘貼。</p><p>  ④模板的拆除:當(dāng)混凝土強(qiáng)度等級(jí)達(dá)到拆模強(qiáng)度后,對(duì)已拆除側(cè)模板的結(jié)構(gòu)及其支撐結(jié)構(gòu)進(jìn)行檢查,確認(rèn)混凝土無影響結(jié)構(gòu)性的缺陷,而結(jié)構(gòu)又有足夠的承載能力后,才能拆除承重模和支架。模板的拆模順序是先承重模板,后承重模板;先側(cè)板,后底板。</p><p>

86、;<b>  5.3.5鋼筋工程</b></p><p>  結(jié)構(gòu)抗震烈度為7度。結(jié)構(gòu)用鋼材保證具有抗拉強(qiáng)度、屈服強(qiáng)度、伸長(zhǎng)率和硫、磷含量的合格保證;對(duì)焊接鋼結(jié)構(gòu)用鋼材,保證具有碳含量、冷彎試驗(yàn)的合格保證。</p><p> ?、俪信_(tái)鋼筋安裝:彈鋼筋位置線→放墊塊→鋪設(shè)承臺(tái)底層鋼筋→綁扎底板鋼筋→二次放線確定柱墻插筋位置→柱墻插筋→申報(bào)隱檢→隱蔽驗(yàn)收→澆灌承臺(tái)、底板砼

87、。底板鋼筋通長(zhǎng)設(shè)置,接頭全部采用焊接,焊接長(zhǎng)度10d,接頭錯(cuò)開50%。為防止柱插筋在澆筑砼過程中位移,在柱墻立筋下端附加Ф12mm水平筋與承臺(tái)底面上層筋綁扎連接,上端用Ф14mm臨時(shí)定位箍點(diǎn)焊固定。</p><p>  ②柱鋼筋:柱鋼筋按七度二級(jí)抗震設(shè)防,柱豎筋接頭d>28時(shí)采用機(jī)械連接, 其余采用綁扎。柱箍均按層施工時(shí),先套入箍筋,然后再接長(zhǎng)縱筋,縱筋接長(zhǎng)后,應(yīng)立即按設(shè)計(jì)要求將柱箍筋上移就位并綁好,以防止

88、縱筋移位,要求將柱頂或柱中兩處箍筋與縱筋焊接,柱頂箍筋還要與主筋焊牢,封柱模時(shí)每邊按1m間距設(shè)兩塊混凝土鋼筋保護(hù)層墊塊。柱與砌體的連接面沿高度每隔500預(yù)埋2φ8鋼筋,埋入柱內(nèi)250,其外伸長(zhǎng)度為700或等于墻垛長(zhǎng)。</p><p> ?、郯邃摻睿核邪褰畈捎么罱咏娱L(zhǎng), 在同一斷面的接頭鋼筋截面面積不得超過鋼筋總截面面積的1/4。雙向板的底筋,其短向筋放在下層,長(zhǎng)向筋放在短向筋之上,且不得在跨中搭接。其在支座的錨

89、固長(zhǎng)度應(yīng)≥5d且伸至梁中心線,板上部鋼筋不得在支座搭接,在非支座處上部鋼筋的腿長(zhǎng)應(yīng)比板厚短15mm。預(yù)留孔洞邊附加筋2φ12,附加筋入墻梁或伸過洞邊450。</p><p> ?、芰讳摻睿毫轰摻顕?yán)格按照樓層框架梁配筋示意和屋面框架梁端支座等梁結(jié)構(gòu)詳圖執(zhí)行。貫通縱筋搭接長(zhǎng)度為50d,所有墻下無梁處, 墻下板底加2φ16, 且就近錨入梁內(nèi), 錨固長(zhǎng)度為750。按實(shí)際保護(hù)層厚度制作對(duì)應(yīng)墊塊和馬凳,底板按1000mm間距

90、綁扎墊塊,梁底及兩側(cè)每100mm在各面墊上兩塊墊塊,確保保護(hù)層厚度。主,次梁底標(biāo)高相同時(shí),次梁下部鋼筋置于主梁下部鋼筋之上。</p><p> ?、蒌摻钸B接:當(dāng)帶肋鋼筋直徑Φ>25 mm時(shí),其最小搭接應(yīng)按相應(yīng)數(shù)值乘以系數(shù)1.1取用; 對(duì)環(huán)氧樹脂涂層的帶肋鋼筋,其最小搭接應(yīng)按相應(yīng)數(shù)值乘以系數(shù)1.25取用; 在混凝土凝固過程中易受擾動(dòng)時(shí),其最小搭接應(yīng)按相應(yīng)數(shù)值乘以系數(shù)1.1取用; 末端采用機(jī)械錨固措施的帶肋鋼筋,其

91、最小搭接可按相應(yīng)數(shù)值乘以系數(shù)0.7取用; 當(dāng)帶肋鋼筋混凝土保護(hù)層厚度大于搭接鋼筋直徑的三倍且配有箍筋時(shí),其最小搭接可按相應(yīng)數(shù)值乘以系數(shù)0.8取用對(duì)有抗震設(shè)防要求的結(jié)構(gòu)構(gòu)件,其受力鋼筋最小搭接長(zhǎng)度對(duì)三級(jí)抗震等級(jí)應(yīng)按相應(yīng)數(shù)值乘以系數(shù)1.05取用,在任何情況下受拉鋼筋的最小搭接長(zhǎng)度不應(yīng)小于300mm。 </p><p>  ⑥鋼筋的堆放:鋼筋要堆放在現(xiàn)場(chǎng)指定的場(chǎng)地內(nèi),掛牌標(biāo)識(shí),標(biāo)識(shí)要注明使用部位、規(guī)格、數(shù)量、尺寸等內(nèi)容

92、。鋼筋標(biāo)識(shí)牌要統(tǒng)一。鋼筋要分類進(jìn)行堆放,如直條鋼筋堆放在一起,箍筋堆放在一起。鋼筋下面一定要墊木架空,防止鋼筋浸在水中生銹。生銹的鋼筋一定要除銹后,由現(xiàn)場(chǎng)鋼筋責(zé)任工程師批準(zhǔn)后使用。</p><p> ?、咪摻畹尿?yàn)收:鋼筋工程屬于隱蔽工程,其驗(yàn)收要求施工班組自檢合格,再由項(xiàng)目工程師邀請(qǐng)建設(shè)方、監(jiān)理方共同驗(yàn)收并辦理鋼筋隱蔽驗(yàn)收手續(xù),經(jīng)驗(yàn)收合格后方可進(jìn)行下一道工序的施工。</p><p>  5

93、.3.6混凝土工程</p><p>  本工程混凝土均采用商品混凝土。</p><p>  混凝土強(qiáng)度要求見工程概況。</p><p>  框架梁與柱相交處混凝土強(qiáng)度以柱為準(zhǔn),因柱混凝土強(qiáng)度等級(jí)高于梁的混凝土等級(jí)</p><p>  混凝土澆筑工藝流程:商品混凝土→運(yùn)送到現(xiàn)場(chǎng)→混凝土運(yùn)送到澆筑部位→底板、柱、梁、板、樓梯混凝土澆筑、振搗及養(yǎng)護(hù)

94、。</p><p>  混凝土澆筑與振搗要求:混凝土自吊斗口或布料管口下落的自由傾落高度不得超過2m,澆筑高度超過2m時(shí),采用串筒,以防混凝土產(chǎn)生離析。振搗方式使用快插慢拔,快插是為了防止上層混凝土振實(shí)后而下層混凝土內(nèi)氣泡無法排出,慢撥是為了能使混凝土能填滿棒所造成的空洞。在振搗過程中,振搗棒略上下抽動(dòng),使混凝土振搗密實(shí),插點(diǎn)要均勻,插點(diǎn)之間距離一控制在50cm,離開模板距離為20cm 。</p>

95、<p>  梁、板澆筑砼,由一端開始用“趕漿法”推進(jìn),先將梁面層澆筑成階梯形,當(dāng)達(dá)到樓板位置時(shí)再與板的砼一起澆筑。第一層下料慢些,使梁底充分振實(shí)后再下第二層料,用“趕漿法”使水泥漿沿梁底包裹石子向前推進(jìn),振搗時(shí)避免觸動(dòng)鋼筋及預(yù)埋件,樓板澆筑的虛鋪厚度略大于板厚,用平板振動(dòng)器垂直澆筑來架捺搗,不斷用移動(dòng)標(biāo)志以控制砼板厚度,振搗完畢采用二次面減少砼收縮裂縫。</p><p>  混凝土的養(yǎng)護(hù)采用自然養(yǎng)護(hù),在

96、澆筑完畢后的12h以內(nèi)對(duì)混凝土澆水保持濕潤(rùn)。待混凝土終凝后,進(jìn)行4~5d的蓄水養(yǎng)護(hù),使混凝土內(nèi)外溫差降至控制范圍之內(nèi),澆水養(yǎng)護(hù)控制在7-14d,在混凝土強(qiáng)度達(dá)到1.2N/mm2前,不得在其上踩踏或安裝模板及支架。</p><p>  施工縫的留設(shè)及處置:內(nèi)墻施工縫可留設(shè)在門洞口過梁跨中1/3范圍內(nèi),也可留在縱橫墻的交接處。梁、板留在跨中1/3范圍內(nèi)。施工縫處混凝土留直槎,嚴(yán)禁留斜坡。施工縫在澆筑下次混凝土之前,已

97、澆混凝土強(qiáng)度不低于1.2N/mm2,已硬化的混凝土表面,應(yīng)剔除表面浮漿及松散混凝土、石子,并用水充分濕潤(rùn)。在澆筑混凝土前,宜先在施工縫處倒一層水泥漿或與混凝土成分相同的水泥砂漿。</p><p><b>  混凝土強(qiáng)度試驗(yàn):</b></p><p><b>  混凝土試塊留置原則</b></p><p>  泵送商品混凝土

98、,混凝土強(qiáng)度試塊在現(xiàn)場(chǎng)澆筑點(diǎn)抽樣檢驗(yàn),留置原則:連續(xù)供應(yīng)同配合比砼大于1000m3時(shí),按每200m3砼不少于一組。少于1000m3時(shí),按每100盤且不超過100m3同配合比砼,取樣不少于一組;每一工作班不足100盤時(shí),取樣仍不少于一組。以28天標(biāo)養(yǎng)試塊強(qiáng)度為依據(jù)。</p><p>  梁板砼另加做留在現(xiàn)場(chǎng)與結(jié)構(gòu)同條件養(yǎng)護(hù)的試塊,作為梁板承重模板拆除時(shí)強(qiáng)度依據(jù)。具體砼試塊組數(shù)按當(dāng)班砼澆筑量進(jìn)行制作。</p&g

99、t;<p>  防水混凝土抗?jié)B試塊留置:當(dāng)砼量在500m3以下時(shí),取樣不少于兩組,且每部位試塊不少于兩組;當(dāng)每增加250~500m3砼時(shí),應(yīng)增加兩組試樣。試塊拆模后即進(jìn)行標(biāo)準(zhǔn)養(yǎng)護(hù)。</p><p><b>  混凝土的質(zhì)量要求:</b></p><p>  (1)混凝土原材料、配合比及拌合物的計(jì)量、攪拌、施工縫留設(shè)和養(yǎng)護(hù)符合施工規(guī)范規(guī)定;</p&g

100、t;<p>  (2)混凝土強(qiáng)度符合規(guī)范GB50204-2002的規(guī)定;</p><p>  (3)表面無蜂窩、孔洞、露筋、施工縫無夾渣等現(xiàn)象;</p><p>  (4)實(shí)測(cè)允許偏差符合《建筑安裝工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)》中防水混凝土及混凝土分項(xiàng)的質(zhì)量要求,其合格率控制在90%以上。</p><p>  混凝土工程技術(shù)質(zhì)量控制措施:</p>

101、<p>  (1)混凝土采購(gòu)選擇</p><p>  按合格分承包方名錄選擇泵送商品混凝土供應(yīng)商。簽訂明確的技術(shù)質(zhì)量職責(zé)、技術(shù)標(biāo)準(zhǔn)及嚴(yán)格的供需合同,保證工程進(jìn)度和質(zhì)量。</p><p>  (2)立足于高性能混凝土設(shè)計(jì)原則,保證施工時(shí)混凝土拌和物具有可靠的耐久性、和易性、強(qiáng)度和體積穩(wěn)定性。在供應(yīng)過程中,嚴(yán)格監(jiān)測(cè)混凝土質(zhì)量,及時(shí)解決施工中可能出現(xiàn)的問題,保證混凝土連續(xù)澆筑。<

102、;/p><p>  (3)嚴(yán)把混凝土驗(yàn)收關(guān)</p><p>  對(duì)混凝土進(jìn)場(chǎng)驗(yàn)收進(jìn)行統(tǒng)一要求,規(guī)定混凝土進(jìn)場(chǎng)須經(jīng)過和易性可泵性驗(yàn)收及車單資料驗(yàn)收檢,并填寫驗(yàn)收表格,不符合要求的混凝土不得使用。派專職試驗(yàn)工檢測(cè)混凝土,記錄進(jìn)場(chǎng)、澆筑開始、結(jié)束及離場(chǎng)時(shí)間。</p><p>  控制商品混凝土可泵質(zhì)量,測(cè)試混凝土坍落度,及時(shí)記錄混凝土澆筑溫度,記錄初凝時(shí)間及終凝時(shí)間。<

103、/p><p>  (4)嚴(yán)把混凝土振搗澆筑關(guān)。通過培訓(xùn),提高振搗手的素質(zhì)水平。</p><p>  采用布料桿泵送混凝土綜合下料技術(shù),控制混凝土分層澆筑厚度。根據(jù)振搗器的型號(hào)、有效半徑對(duì)豎向構(gòu)件混凝土的分層厚度進(jìn)行計(jì)算,澆筑時(shí)嚴(yán)格按澆筑厚度下混凝土。按操作規(guī)程施工,達(dá)到結(jié)構(gòu)榕城杯質(zhì)量標(biāo)準(zhǔn)。</p><p>  (5)嚴(yán)格控制混凝土澆筑接槎時(shí)間</p>&l

104、t;p>  認(rèn)真計(jì)算分層澆筑混凝土的用量,根據(jù)估算出的混凝土初凝前必須完成的混凝土量,計(jì)算出均勻供應(yīng)的速度,進(jìn)而周密考慮現(xiàn)場(chǎng)布料桿、塔吊等工作效率。合理組織,使混凝土接槎在規(guī)定時(shí)間內(nèi)完成,確保不出現(xiàn)冷縫。</p><p>  (6)嚴(yán)把混凝土抹面關(guān)</p><p>  由于混凝土設(shè)計(jì)坍落度較大,為避免樓板特別是厚度較大的樓板面混凝土因沉實(shí)產(chǎn)生裂縫,要堅(jiān)持在混凝土初凝和終凝之間進(jìn)行二次

105、或三次抹面,防止開裂。并且嚴(yán)格控制上人和上料時(shí)間,控制好覆蓋的溫度和覆蓋時(shí)間,防止上人過早。</p><p>  (7)強(qiáng)化混凝土施工試驗(yàn)工作,嚴(yán)格按規(guī)范要求留設(shè)混凝土試塊。</p><p><b>  5.3.7砌體工程</b></p><p><b>  材料要求:</b></p><p>  

106、磚材有按批量的出廠合格證明書,進(jìn)場(chǎng)后進(jìn)行外觀檢測(cè):質(zhì)地堅(jiān)硬、表面平整、色澤均勻、棱角方正,無彎曲、無裂紋、無鼓皮、火力燒透、敲出聲音響亮,孔洞均勻。按規(guī)定進(jìn)行抽樣復(fù)檢,復(fù)檢認(rèn)定合格后方可使用。承重磚具備力學(xué)性能試驗(yàn)報(bào)告。</p><p>  砌筑用水泥有出廠合格證及檢驗(yàn)報(bào)告單,對(duì)出廠期已超過3個(gè)月或已受潮、結(jié)塊的水泥,應(yīng)重新復(fù)檢,合格后方可使用。</p><p><b>  施工

107、方法及要求:</b></p><p>  砌體施工前,根據(jù)施工圖紙彈出墻體位置線,豎皮數(shù)桿,控制砌體施工時(shí)的灰縫厚度和斜砌的高度。</p><p>  磚的砌筑做到上下、內(nèi)外搭砌,附墻垛及轉(zhuǎn)角的砌體要防止包心砌法和錯(cuò)縫小于60mm的內(nèi)通縫。砌體砂漿飽滿、磚縫均勻,水平及豎直灰縫厚度為8~10mm。</p><p>  當(dāng)砌筑磚厚大于90mm時(shí),采用“掛、

108、填、鋪砌法”?!皰?、填、鋪砌法”是先鋪水平灰(長(zhǎng)度不大于500mm),于磚頭掛豎灰后擠砌,對(duì)不滿的豎縫用勾抹子再行勾填飽滿的方法。</p><p>  外墻采用承重磚砌筑,為提高砌體防水能力,外墻的磚選擇棱角齊全、豎縫接觸面飽滿度達(dá)到75%以上。不飽滿的要當(dāng)班進(jìn)行有效的修填勾平??蚣芰旱鬃詈笠黄ごu待墻體砂漿沉實(shí)后再用斜砌方法進(jìn)行組砌,梁底用高一等級(jí)的砂漿堵填密實(shí)。</p><p>  墻體

109、沿框架柱、剪力墻按設(shè)計(jì)要求留設(shè)拉結(jié)筋。</p><p><b>  砂漿強(qiáng)度試驗(yàn):</b></p><p>  砂漿試塊留置原則:砂漿強(qiáng)度等級(jí)以標(biāo)準(zhǔn)養(yǎng)護(hù)(或同條件自然養(yǎng)護(hù))、齡期為28天的試塊試壓檢驗(yàn)結(jié)果為準(zhǔn)。每一樓層或250立方米砌體中的各種強(qiáng)度等級(jí)(含每一試驗(yàn)配合比)的砂漿,至少作二組試塊供試驗(yàn)評(píng)定。試塊拆模后即進(jìn)行標(biāo)準(zhǔn)養(yǎng)護(hù)。</p><p&g

110、t;<b>  質(zhì)量要求:</b></p><p>  (1)砌體用磚、砂漿、配合比及其計(jì)量、攪拌、強(qiáng)度等符合設(shè)計(jì)和驗(yàn)評(píng)標(biāo)準(zhǔn)規(guī)定;</p><p>  (2)砌體砂漿水平灰縫飽滿度、留槎做法符合施工規(guī)范規(guī)定;</p><p>  (3)砌體的錯(cuò)縫、接槎、拉結(jié)筋設(shè)置、構(gòu)造柱等符合設(shè)計(jì)和驗(yàn)評(píng)標(biāo)準(zhǔn)規(guī)定;</p><p>  (

111、4)實(shí)測(cè)允許偏差符合《建筑安裝工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)》中砌磚分項(xiàng)的質(zhì)量要求,其合格率控制在90%以上。</p><p><b>  5.3.8防水工程</b></p><p><b>  1.層面防水</b></p><p>  屋面防水采用高聚物改性瀝青卷材和涂膜防水。具體做法為100厚,C30預(yù)制混凝土板,縫寬3—5,1

112、:1水泥砂漿填縫→鋪25厚中砂→二層3厚SBS或APP改性瀝青防水卷材→刷基層處理劑一遍→20厚1:2.5水泥砂漿找平層→40厚水泥石灰焦渣砂漿找坡→層面板表面清除。</p><p>  2.衛(wèi)生間、清洗間、污物間、陽臺(tái)、外走廊防水</p><p>  設(shè)防標(biāo)準(zhǔn)及防水層次:一道設(shè)防或復(fù)合防水。</p><p>  防水材料:防水涂料(厚度≥2.0mm)。</p

113、><p>  設(shè)防要求及質(zhì)量保證措施:空心砌塊等輕質(zhì)隔墻做300mm, C20的混凝土墻基,厚與墻體相同;衛(wèi)生間的內(nèi)墻應(yīng)全部做防水處理。地面找坡,坡向地漏(或地溝)找坡坡度≥1%;地漏及穿地管道待安裝完畢后用細(xì)石混凝土封嚴(yán)管根及地漏的周圍用防水膠等密封材料封嚴(yán),并與防水層閉合。</p><p><b>  3.外墻防水</b></p><p>  

114、設(shè)防標(biāo)準(zhǔn):一道設(shè)防或復(fù)合防水</p><p>  防水材料:聚合物水泥砂漿(厚度≥7.0mm)。</p><p>  設(shè)防要求及質(zhì)量保證措施:空心砌塊外墻門窗洞口周邊200mm范圍內(nèi)應(yīng)用實(shí)心砌體或者C20細(xì)石砼填實(shí)。外窗窗樘與墻體之間的填縫,應(yīng)采用聚合物水泥砂漿填實(shí),窗下口安裝縫隙要根據(jù)室外窗臺(tái)飾面厚度預(yù)留充分,確保窗下樘雨水能順暢排出。外墻不同材料交接處應(yīng)在找平層中附加18#金屬網(wǎng),網(wǎng)寬

115、為300mm。找平層的強(qiáng)度等級(jí)不應(yīng)低于M7.5,與墻體基面的抗拉粘結(jié)強(qiáng)度不宜低于0.4MPa,以防止外墻的鼓裂問題。</p><p><b>  6 施工平面布置</b></p><p>  6.1施工總平面布置依據(jù)</p><p>  根據(jù)施工工藝流程,各種設(shè)計(jì)資料,業(yè)主提供的現(xiàn)場(chǎng)場(chǎng)內(nèi)地下及周圍環(huán)境、作業(yè)條件,項(xiàng)目所在的地方政府的有關(guān)規(guī)定等。

116、</p><p>  6.2施工總平面布置原則</p><p>  平面布置應(yīng)在滿足施工工藝流程要求的前提下盡量緊湊,盡量縮短運(yùn)輸路線及各種管線的距離和長(zhǎng)度;充分考慮防火和技術(shù)安全要求;便于工人的生活與生產(chǎn)。</p><p>  6.3現(xiàn)場(chǎng)道路及排水</p><p>  施工現(xiàn)場(chǎng)主要施工道路基土夯實(shí)壓平,上鋪混凝土,保證砂漿攪拌機(jī)、鋼筋運(yùn)輸車

117、。為保證施工的安全,建筑物出入口上方必須按照規(guī)范要求設(shè)置為護(hù)頭棚。道路兩側(cè)設(shè)300×200磚砌排水溝,路面向排水溝進(jìn)行找坡,通過排水溝排入市政管道?,F(xiàn)場(chǎng)道路圍繞建筑物布置成一系環(huán)形道路,道路寬度5m。</p><p>  6.4現(xiàn)場(chǎng)機(jī)械、設(shè)備的布置</p><p>  根據(jù)本工程的建筑面積及建筑尺寸,在現(xiàn)場(chǎng)布置2個(gè)施工電梯,以滿足各種施工條件和施工要求。(具體位置詳見施工總平面布

118、置圖)</p><p>  1.鋼筋加工棚在靠近鋼筋堆放場(chǎng),部分加工好的鋼筋有塔吊協(xié)助運(yùn)輸至倒運(yùn)場(chǎng)地,其他材料、模板、鋼筋的布置依據(jù)就近堆放設(shè)置。</p><p>  2.在平面上布置一臺(tái)混凝土輸送泵負(fù)責(zé)混凝土輸泵送澆筑。</p><p>  6.5現(xiàn)場(chǎng)材料加工、堆放場(chǎng)地</p><p>  大型鋼筋、模板加工場(chǎng)以及各種材料碼放場(chǎng)地根據(jù)現(xiàn)場(chǎng)場(chǎng)

119、地的情況,考慮施工運(yùn)輸距離短,吊送合理,沿建筑物周圍設(shè)置、堆放。本工程結(jié)構(gòu)施工所用的混凝土全部采用預(yù)拌商品混凝土,因此現(xiàn)場(chǎng)不設(shè)混凝土攪拌場(chǎng)地。根據(jù)現(xiàn)場(chǎng)作業(yè)棚所需面積參考指標(biāo),以及各材料的周轉(zhuǎn)時(shí)間,同時(shí)參考類似工程的的施工平面布置圖,確定其堆放面積見表6-1。</p><p>  7.0施工組織及施工進(jìn)度計(jì)劃</p><p>  7.1施工段的劃分 </p><p>

120、;  本工程施工全過程有基礎(chǔ)工程、主體工程、裝飾工程、屋面工程、設(shè)備安裝工程,從基礎(chǔ)工程開始到主體工程完成,由西向東平行均衡流水(不等高式)施工。 </p><p><b>  7.2主要工序</b></p><p>  本工程總的工程序?yàn)橄鹊叵潞蟮厣?,先土建后設(shè)備安裝,先結(jié)構(gòu)后裝飾。 </p><p>  基礎(chǔ)工程:采取由下而上的施工順序施工

121、: </p><p>  主體結(jié)構(gòu):施工時(shí),采取平行流水不等高式施工,由下而上逐層分段流水施工。</p><p>  裝飾工程:主體結(jié)構(gòu)完成之后,邀請(qǐng)質(zhì)量監(jiān)督部門對(duì)主體工程乾地質(zhì)量檢查,驗(yàn)收合格后,方可施工。施工時(shí),自上而下逐層進(jìn)行內(nèi)裝修,待女兒墻壓頂完成后,自上而下進(jìn)行外裝飾。室內(nèi)外裝飾不分施工段,采承先內(nèi)部、后外部。</p><p>  根據(jù)本工程特點(diǎn),為了有利

122、于結(jié)構(gòu)的整體性,減少建筑物的施工縫,因而,從基礎(chǔ)工程開始到主體工程完成,采取平行流水施工:即:由西向東流水施工。 </p><p>  7.3 勞動(dòng)力安排 </p><p>  勞動(dòng)力組織采用按工種分組施工的方式,統(tǒng)一調(diào)度各工種的施工力量組織施工。根據(jù)本工程的工作量、進(jìn)度要求等因素,高峰期二班倒選用勞動(dòng)力達(dá)126人。在裝修期間和水、電、 設(shè)備安裝工程由專業(yè)人員配合施工。</p>

123、<p>  7.4 施工進(jìn)度計(jì)劃 </p><p>  結(jié)構(gòu)工程的施工周期,約占總工期的60%以上, 且易受自然氣候的影響,當(dāng)進(jìn)入標(biāo)準(zhǔn)層施工后,人員、設(shè)備的運(yùn)轉(zhuǎn)日趨正常,為確保階段工期的實(shí)現(xiàn),分項(xiàng)工程工期按如下五個(gè)階段進(jìn)行綜合控制: </p><p>  (1)基礎(chǔ)工程工期28日歷天。 </p><p>  (2)首層、頂層工期各10天,標(biāo)準(zhǔn)層每6天

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 眾賞文庫(kù)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論