APL白血病多元微球陣列的定量方法研究.pdf_第1頁
已閱讀1頁,還剩61頁未讀 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡介

1、山東輕工業(yè)學(xué)院碩士學(xué)位論文APL白血病多元微球陣列的定量方法研究姓名:王進(jìn)申請(qǐng)學(xué)位級(jí)別:碩士專業(yè):發(fā)酵工程指導(dǎo)教師:蘭文軍2011-05-30山東輕工業(yè)學(xué)院碩士學(xué)位論文 I ABSTRACT This study addressed the preparation of polystyrene beads, the encoding of fluorescein isothiocyanate (FITC) and the analysi

2、s of multiplexed bead array for acute promyelocytic leukemia (APL). Polystyrene beads in this study were synthesized by styrene polymerization reaction. FITC dye was used to encode polystyrene beads as two bead populatio

3、ns in which the high brightness beads were coated with anti-PML antibody to capture PML-RARα fusion protein, and the low brightness beads were conjugated with homotype control antibody to perform the background control.

4、Report antibody identified by PE-labeled antibody can recognise RAR alpha peptide epitope in fusion protein captured by the high-light beads. Thus PML-RARα fusion protein can be quantified via detecting PE fluorescence i

5、ntensity using flow cytometer. We firstly studied the effect of reagent adding approach, reaction time, stabilizer and crosslinker dosage on microspheres diameter and coefficient of variation. Electron microscope assay e

6、xhibited that 5.4 µm polystyrene beads with functional groups can be successfully polymerized, when a mixture containing 6 g stabilizer, 0.3 g crosslinker, a carboxylic acid and a amino compound was reacted for 12 h

7、r. Next this paper studied the action of FITC concentration and reaction time to functional beads encoding. Flow cytometry appeared that the high brightness and low brightness beads, which constructed the duplexed beads

8、 array, can be successfully encoded by 0.4 µL and 125 µL FITC fluorescence solution after 0.5 hour incubation. APL duplexed beads array were also tested in this study. Flow cytometry showed results as followin

9、g: a, PML-RARα fusion protein in NB4 cell line can be specially detected by the duplexed beads array. b, The value of array sensitivity was 0.63%. c, The coefficient of variation between different batch array was less th

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 眾賞文庫僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論